Service Hotline:400-688-3551
Home » News Center
— News Center 

Recommended Products

Product characteristics: high air volume, high static pressure, high efficiency, low noise

Multiple safety devices: current overload protection circuit, fault indication, fault

Humanized ingenuity: with carrying handle, easy to carry and install, beautiful appearance

Product model: FK-15CDCSAN1
Mainly used for terminal filtration in electronics, biopharmaceutical industries and hospitals where high cleanliness is required.

Frame material: anodized aluminum profile

Frame thickness: 50mm, 70mm, 90mm

Product model: GWB-4.5A, GWB-9A, GWB-18A, GWB-4.8A

GWB-10.3A, GWB-13A, GWB-15.7A, GWB-21A, GWB-

4.5B
Mainly used for terminal filtration in electronics, biopharmaceutical industries and hospitals where high cleanliness is required.

Frame material: anodized aluminum profile

Frame thickness: 50mm, 70mm, 90mm

Product attributes: SWB-4.5A, SWB-9A, SWB-18A, SWB-2.9A

SWB-6A, SWB-7.6A
It is mainly used for terminal filtration in applications requiring high cleanliness, such as electronics, biopharmaceutical industry and hospitals.

Frame material: aluminum alloy, galvanized sheet, wooden board, stainless steel

Frame thickness: 150mm, 220mm, 292mm

Product model: GHB-2.5A, GHB-5A, GHB-10A, GHB-15A

GHB-20A, GHB-5B, GHB-10B
Coarse dust filtration system for general building air conditioning. Primary filtration of industrial-grade air ventilation equipment.

Frame material: galvanized frame, aluminum alloy frame or stainless steel frame

Frame thickness: 10, 21, 46, 96, etc.

Product model: CJ-17A, CJ-34A, CJ-17B, CJ-34B
Ventilation systems for office buildings, meeting rooms, hospitals, shopping malls, stadiums, airports and other large civil buildings.

Outer frame material: aluminum alloy frame, can be made into a whole group with handle interconnection, easy and safe to replace

Frame thickness: 10, 21, 46, 96, etc.

Product model: CN-24A, CN-28.5A, CN-34A, CN-17B, CN-

24B, CN-28.5B, CN-34B, CN-17C, CN-24C, CN-28.5C

CN-34C
Product features: no partition design, lower running resistance, wide application range, compact structure, saving storage space

Product application: In the high-efficiency air outlet of the clean room of the pharmaceutical plant, the FFU products of the purification plant are equipped with high-efficiency filters

Efficiency: 99.97%@0.3μm (H13); 99.99%@0.3μm (H14);

Product model: GPW-8-470-D, GPW-8-1000-D, GPW-8-

260-D, GPW-8-550-D, GPW-9.3-470-B
Contact Us
Tel: +86 13355281100
phone: 400-688-3551
fax: 0531-82076779
mailboxsales@snyli.com
Factory Address: No. 16 Heilongjiang Road, Economic Development Zone, Liaocheng City, Shandong Province
Factory Address: West End of Weisi Road, Linzi District, Zibo City, Shandong Province

Cleanroom

These are related to the Cleanroom news, in which you can learn about the latest trends in Cleanroom and related information industry, to help you better understand and expand Cleanroom market.
  • Clean technology||Clean room ventilation frequency standard reference
    2021-09-26

    (1) In the clean room standards of various countries, the number of air changes in non-unidirectional flow clean rooms of the same level are not the same.my country's \"Code for Design of Clean Workshops\" (GB 50073-2001) clearly stipulates the number of experience air changes required for calculation of clean air supply for different levels of non-unidirectional flow clean rooms, as shown in the following table:

  • Cleanroom three-stage filtration system
    2021-09-24

    The definition of clean room is a room where the concentration of airborne particles is controlled.Its construction and use should reduce indoor induction, generation and retention of particles.Other relevant indoor parameters such as temperature, humidity, pressure, etc. are controlled as required.A measure of clean room cleanliness: the degree of cleanliness distinguished by the number of particles of a certain particle size per unit volume of air.Cleanliness level:

  • Clean room change
    2021-08-05

    In the clean room standards in each country, the number of non-single stream cleaning chambers of the same level is not the same. my country's \"Clean Plant Design Specification\" (GB 50073-2001) clearly stipulates the number of experiences required for different levels of different levels of freedom of clean and delivering air volume, see below:

  • Clean room change
    2021-08-05

    In the clean room standards in each country, the number of non-single stream cleaning chambers of the same level is not the same. my country's \"Clean Factory Design Specification\" (GB 50073-2001) clearly stipulates that the number of experiences required for different levels of non-single-way streamlined cleaning air supply calculations required, see below: Remarks: Number of ventilation is suitable A clean room with a layer of less than 4.0m. The room is small, and the lower limit is adopted. Clean room with more than 100,000 level is not less than 12 times. In addition: Experimental animal environment and facility national standard GB14925-2001 specifies that the normal environment 8-10 / h barrier environment 10-20 isolation environment 20-50 1. Temperature and relative humidity clean room (zone) temperature and relative humidity should be related to drugs The production process is compatible. When there is no special requirements, the temperature should be controlled at 18 to 26 ° C, and the relative temperature should be controlled at 45% to 65%. two,

  • Influence of clean room backham system design on clean room
    2021-07-30

    With the continuous development of science and technology, the production and modern scientific experiment activities of modern industrial products are increasingly high, especially microelectronics, biopharmaceuticals, medical institutions, precision manufacturing, food processing, etc. Have high quality, high purity, high reliability indoor environment. Air clean technology has become an indispensable basic conditions for modern industrial production, medical and scientific experimental activities, and is an important means to ensure product quality and environmental safety, which are increasingly widely used in various industries. Clean room has a certain air cleanliness level, controlling multiple parameters (air cleanliness, air volume, wind speed, pressure, temperature, humidity, bacterial concentration, etc.). Clean air conditioning system is the main means of implementing clean room control. The clean air conditioning system mainly has the following characteristics compared to the general construction air conditioning system: 1) Ensure the temperature and humidity of the production process; 2) Guaranteed the net

Website:www.snyli.com               Mobile: 13355281100
Service Hotline: 400-688-3551    Mailbox:sales@snyli.com
Telephone: 0533-6217678
Factory Address: No. 16 Heilongjiang Road, Economic Development Zone, Liaocheng City, Shandong Province
Factory Address: West End of Weisi Road, Linzi District, Zibo City, Shandong Province
Copyrigh ©2019 Shandong Snyli [Snyli Environmental Technology (Shandong) Co., Ltd., Shandong Snyli Purification Technology Co., Ltd.] All Rights Reserved.
Lu ICP No. 16035622-1  Technical Support:Yi Qilai